Difference between revisions of "RoboThespian Installation Overview and Requirements"

From Engineered Arts Wiki
Jump to navigation Jump to search
(Minimum Installation Requirements)
(Compressed air)
Line 21: Line 21:
 
* Extra 8mm outside diameter polyeurethane tubing can be supplied on request<section end=installation requirements />
 
* Extra 8mm outside diameter polyeurethane tubing can be supplied on request<section end=installation requirements />
  
==Compressed air==
+
===Compressed air===
 
<section begin=compressed air />
 
<section begin=compressed air />
 
For customers that do not have a fixed supply of compressed air, we recommend the following portable air compressors for use with RoboThespian:   
 
For customers that do not have a fixed supply of compressed air, we recommend the following portable air compressors for use with RoboThespian:   

Revision as of 09:40, 15 March 2016

This is a protected page.

Overview

RoboThespian has a straightforward setup.

Setup Layout

  • RoboThespian Setup

Minimum Installation Requirements

  • Suitable for indoor use only. Recommended room temperature: 10°C - 30°C, relative humidity: 45% - 60%
  • Standard domestic mains power in the range 100v - 250v AC
  • Un-oiled, compressed air at 6bar, filtered to 10µm. Peak air consumption 30L/min at 6bar maximum, on average consumption is much less.
  • A barrier to prevent contact between visitors and RoboThespian.
  • Wired network connection - required for remote support, fault resolution, and the application of updates and new software/content features.
  • Airline connection to robot is via an 8mm outside diameter Push-In-Fitting
  • Extra 8mm outside diameter polyeurethane tubing can be supplied on request

Compressed air

For customers that do not have a fixed supply of compressed air, we recommend the following portable air compressors for use with RoboThespian:

Jun-Air Model OF302-25B Portable Air Compressor

Jun-Air Model OF302-25M Portable Air Compressor

Always check and familiarise yourself with the operating instructions for the compressor.

Base Dimensions

  • RoboThespian Base Dimensions

RoboThespian can also be installed directly onto a stage. For this application a low-profile version of the base is available. A hole in the base, allows cables to be neatly routed down into the stage. The robots DC power supply unit can also be located directly below him, we recommend a hole in the stage 150mm in diameter under the base.

Hole layout for feet - if mounting directly on own base / stage

Should you want to mount RoboThespian directly on your own stage or base, please use the following hold template:

  • Hole layout

Downloadable template here: RT3-feet-drill-pattern.pdf

Print template at 1:1 scale (i.e. do not scale to fit page when print). Check dimensions against a ruler before using.

Touchscreen kiosk Dimensions

The touch screen kiosk is the most common way in which visitors can interact with the robot. It also offers staff the ability to adjust settings and shut down the robot. For full details of the touchscreen functionality please see Touchscreen

Kiosk dimensions (for information only):

  • Kiosk dimensions


The kiosk is supplied with 5m of cabling to RoboThespian.

Base and Kiosk Colour Options

The bases and kiosks can be supplied as:

  • black laminate
  • white laminate
  • Black or white laminated kiosks

Reference Stage Design

  • RoboThespian Reference Stage Design

Downloadable drawing with recommended stage dimensions in pdf format:

RoboThespian stage design.pdf

Example Stage Areas

  • RoboThespian at National Science Museum, Thailand
  • RoboThespian at Questacon, National Science Museum of Australia
  • RoboThespian at Carnegie Science Center Roboworld gallery
  • RoboThespian at NASA's Kennedy Space Center Visitor's Complex