=Introduction=
 
=Introduction=
 
This page gives an overview of the installation requirements for RoboThespian and examples of stage areas for anyone new to RoboThespian.
 
This page gives an overview of the installation requirements for RoboThespian and examples of stage areas for anyone new to RoboThespian.
Line 19: Line 19:
 
* Standard domestic mains power in the range 100v - 250v AC
 
* Standard domestic mains power in the range 100v - 250v AC
 
* A barrier to prevent contact between visitors and RoboThespian.
 
* A barrier to prevent contact between visitors and RoboThespian.
* Wired internet network connection with good bandwidth - required for remote support, fault resolution, and the application of updates and new software/content features.see [[Network Setup]]<section end=installation requirements />
+
* Wired internet network connection with good bandwidth - see [[Network Setup]].  Required for [[TinMan Telepresence]] , [[Remote Connection|remote administration]] and support, and the application of updates and new software/content features.  
* Un-oiled, compressed air at 6bar, filtered to 10µm. Peak air consumption 30L/min at 6bar maximum, on average consumption is much less.
+
* Un-oiled, compressed air at 6bar (87psi), filtered to 10µm. Peak air consumption 30L/min (7.9 US gpm) at 6bar (87psi) maximum, on average consumption is much less (Engineered Arts can supply a suitable portable air compressor unit if no fixed supply available)
* Airline connection to robot is via an 8mm outside diameter Push-In-Fitting.
+
* Airline connection to robot is via an 8mm (5/16in) outside diameter Push-In-Fitting.
* Extra 8mm outside diameter polyeurethane tubing can be supplied on request.
+
* Extra 8mm (5/16in) outside diameter polyeurethane tubing can be supplied on request. <section end=installation requirements />
  
 
== Example Stage Areas ==
 
== Example Stage Areas ==
Line 39: Line 39:
 
</ul></div>
 
</ul></div>
  
Downloadable drawing with recommended stage dimensions in pdf format:  
+
Download the reference stage design with dimensions here: [[Media:RoboThespian stage design.pdf]]
 
 
[[File:RoboThespian stage design.pdf]]
 
 
 
  
 
==Base Dimensions==
 
==Base Dimensions==
Line 58: Line 55:
 
</ul></div>
 
</ul></div>
  
Downloadable and printable template here:
+
Download the printable template here: [[Media:RT3-feet-drill-pattern.pdf]]
 
 
<div><ul>
 
<li style="display: inline-block;">[[File:RT3-feet-drill-pattern.pdf|thumb|none|340px|link=|Hole layout - download and print]]</li>
 
</ul></div>
 
  
 
Print template at 1:1 scale (i.e. do not scale to fit page when print).  Check dimensions against a ruler before using.
 
Print template at 1:1 scale (i.e. do not scale to fit page when print).  Check dimensions against a ruler before using.
Line 76: Line 69:
  
 
<div><ul>
 
<div><ul>
<li style="display: inline-block;">[[File:lightweight_kiosk_dimensions.png|thumb|none|1200px|link=|Kiosk dimensions]]</li>
+
<li style="display: inline-block;">[[File:lightweight_kiosk_dimensions.png|thumb|none|1000px|link=|Kiosk dimensions]]</li>
 
</ul></div>
 
</ul></div>
  
Line 88: Line 81:
 
*Suitable for installations where the compressor can be located in a separate room to the robot due to noise level.
 
*Suitable for installations where the compressor can be located in a separate room to the robot due to noise level.
 
*Noise level is 65-66 dB(A) – comparable to a hairdryer.
 
*Noise level is 65-66 dB(A) – comparable to a hairdryer.
*Technical Spec:  http://www.jun-air.com/product_detail.aspx?ProductID=572&ProductTypeID=49
+
*Technical Spec:  https://jun-air.com/wp-content/uploads/2022/03/March-2022-OF302-25B-Rev-D.pdf
  
 
Jun-Air Model OF302-25M Portable Air Compressor     
 
Jun-Air Model OF302-25M Portable Air Compressor     
 
*Compressor is contained in an acoustic housing to reduce noise level.
 
*Compressor is contained in an acoustic housing to reduce noise level.
 
*Noise level 47-48 dB(A) – quiet enough to be located very close to robot without causing distraction.
 
*Noise level 47-48 dB(A) – quiet enough to be located very close to robot without causing distraction.
*Technical Spec:  http://www.jun-air.com/product_detail.aspx?ProductID=574&ProductTypeID=49
+
*Technical Spec:  https://jun-air.com/wp-content/uploads/2022/03/March-2022-OF302-25M-Rev-D.pdf
  
 
Always check and familiarise yourself with the operating instructions for the compressor.<section end=compressed air />
 
Always check and familiarise yourself with the operating instructions for the compressor.<section end=compressed air />

Latest revision as of 11:23, 22 September 2022

RoboThespian >> RoboThespian Installation Overview and Requirements

Introduction

This page gives an overview of the installation requirements for RoboThespian and examples of stage areas for anyone new to RoboThespian.

Setup Layout

Setup is straightforward, consisting of a robot, a touchscreen kiosk for easy public interaction and (optionally) a portable air compressor.

  • RoboThespian Setup

For detailed unpacking and assembly instructions see RoboThespian Unpacking & Assembly and watch the video.

Minimum Installation Requirements

  • Suitable for indoor use only. Recommended room temperature: 10°C - 30°C, relative humidity: 45% - 60%
  • Standard domestic mains power in the range 100v - 250v AC
  • A barrier to prevent contact between visitors and RoboThespian.
  • Wired internet network connection with good bandwidth - see Network Setup. Required for TinMan Telepresence , remote administration and support, and the application of updates and new software/content features.
  • Un-oiled, compressed air at 6bar (87psi), filtered to 10µm. Peak air consumption 30L/min (7.9 US gpm) at 6bar (87psi) maximum, on average consumption is much less (Engineered Arts can supply a suitable portable air compressor unit if no fixed supply available)
  • Airline connection to robot is via an 8mm (5/16in) outside diameter Push-In-Fitting.
  • Extra 8mm (5/16in) outside diameter polyeurethane tubing can be supplied on request.

Example Stage Areas

  • RoboThespian at Suzhou Robot Museum, China
  • RoboThespian at National Science Museum, Thailand
  • RoboThespian at Questacon, National Science Museum of Australia
  • RoboThespian at Questacon, in foyer, July 2017
  • RoboThespian at Carnegie Science Center Roboworld gallery
  • RoboThespian at NASA's Kennedy Space Center Visitor's Complex

Reference Stage Design

  • RoboThespian Reference Stage Design

Download the reference stage design with dimensions here: Media:RoboThespian stage design.pdf

Base Dimensions

  • RoboThespian Base Dimensions

RoboThespian can also be installed directly onto a stage. For this application a low-profile version of the base is available. A hole in the base, allows cables to be neatly routed down into the stage. The robots DC power supply unit can also be located directly below him, we recommend a hole in the stage 150mm in diameter under the base.

Hole layout for feet - if mounting directly on own base / stage

Should you want to mount RoboThespian directly on your own stage or base, please use the following hold template:

  • Hole layout

Download the printable template here: Media:RT3-feet-drill-pattern.pdf

Print template at 1:1 scale (i.e. do not scale to fit page when print). Check dimensions against a ruler before using.

Press fit 8 off M8 threaded prong nuts (tee nuts) into the underside of the base for fastening RoboThespian onto:

  • Threaded pronged tee nuts

Touchscreen kiosk Dimensions

The touch screen kiosk is the most common way in which visitors can interact with the robot. It also offers staff the ability to adjust settings and shut down the robot. For full details of the touchscreen functionality please see Touchscreen

  • Kiosk dimensions

The kiosk is supplied with 5m of cabling to RoboThespian.

Recommended Compressors

For customers that do not have a fixed supply of compressed air, we recommend the following portable air compressors for use with RoboThespian. These can be supplied by Engineered Arts with your robot.

Jun-Air Model OF302-25B Portable Air Compressor

Jun-Air Model OF302-25M Portable Air Compressor

Always check and familiarise yourself with the operating instructions for the compressor.